高低温湿热交变试验箱

价 格:¥188

型 号:TH-G-408

产品完善度:

生产地:其他访问量:510次

发布日期:2009/11/2 0:00:00

更新日期:2009/8/8 13:50:19

详细内容

Temperature & Humidity chamber (Floor type)
Standard environmental test chambers
Select your optimum chamber from a full variation - this series provide three variations in temperature (& humidity) range of -35 to 150℃, -35 to 120℃, -60 to 150℃ with upmost 20 to 98% RH.
Model name
TH/TC-G/I-180 (180L)
TH/TC-G/I/GU-300 (300L)
TH/TC-G/I-408 (408L)
TH/TC-G-800 (800L)
TH/TC-G/I-1000 (1000L)
CE BDBC2 GREEN

User-friendly design
? Standard environmental test chambers
? High quality 304 stainless steel exterior and interior
? Casters for easy transport and installation
? Convenient maintenance - available to check total operating time
? Enough chamber capacity up to maximum 1000L
? Select your optimum chamber from a full variation
  - The series provide three variations in temperature (& humidity) range of -40 to 150℃, -40 to 120℃, -60 to 150℃/
    upmost 20 to 98% RH, and five capacities of 180L, 300L, 408L, 800L, and 1000L, with a total 15 models altogether

 

? Exclusive door lock & trim
  - Vice lock type door catch and foamed silicone packing ensure perfect chamber seal
  - Door open warning alarm

? Inner door
  - Optional inner glass door has four hole to handle inside specimen without opening the door
    (Except for 800L and 1000L)

? Ventilation
  - Ventilation vent is located at the upper right side of the unit

? Recorder (optional)
  - 6-point dots type recorder with digital display

? Cartridge type tank for easy water supply
  - Maintenance can be done easily from the front side
  - A center window allow to check the amount of water remaining easily

? Viewing window for observation
  - A tempered window provides a clear view of your specimen during testing
  - Improved lighting provided

? Access port for running in wires
  - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen.
    We also provide additional 50 or 80mm diameter cable port (Optional)

? Easy cleaning of condenser air-filter
  - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning



Control operation
? Microprocess PID control/ Auto-tuning/ Calibration
? Setting and indication resolution: Temp.: 0.01℃, Humid.: 0.1%
? Languages support in three kinds of English, Chinese, and Korean

? Optimize CPU logic control system
  - Optimum control for temperature/ humidity with economical control in power consumption

? Touch screen type monitor
  - 5.7-inch color LCD with interactive input system using touch keys
  - Temperature & humidity/ timer settings and operating condition
  - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form
  - Easily recognizable set values: set point (SP) / proportional value (PV) are also added on the color LED controller

? Programming operation

Description TH-G/ I/ GU, TC-G/ GU series
Programmable pattern capacity 120
Pattern repeat time 999
Max. segments per a pattern 100
Available max. segments * 1200
Programmable process time per a segment 0 to 99 hr 59 min
* Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000,
  so you need to arrange the number of segment and patterns properly.

? Computer interface (optional)
  - Available to save all data in Excel
  - Provide a software
  - The program information, setting values backup/ recovery, and temperature/ humidity values storage

Safety functions
? Leakage breaker for power supply
? Over current protector
? Overheat/ overcool protectors
? Switch-off after alarm for over heating
? Water empty (TH-G/ TH-GU/ TH-I only)
? Door opening alarm
? Vice lock door closing equipment

Model TH-G-180 TH-G-300 TH-G-408 TH-G-800 TH-G-1000
Chamber volume (L/cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling Control
Controller Programmable, Touch screen type controller (5.7" B/W monitor)
Temperature Range(℃/℉) -35 to 150 / -31 to 302 - without humidity
* Best programmable control range: -30 to 140 / -22 to 284
Fluctuation1)
(±℃/℉)
at 55℃ / 60%RH
0.1 / 0.18
0.2 / 0.36
0.2 / 0.36
0.3 / 0.55
0.3 / 0.55
Variation1)
(±℃/℉)
at 55℃ / 60%RH
0.6 / 1.08
0.5 / 0.9
0.5 / 0.9

0.5 / 0.9

0.5 / 0.9
Time Heating-without
humidity(Min.)
50 From -40℃ to 120℃ (-31℉ to 248℉) 60 From -40℃ to 120℃ (-31℉ to 248℉)
Cooling-without
humidity(Min.)
60 From 20℃ to - 35℃ (68℉ to -31℉) on single point control *
Humidity Range(%RH) 40 to 85% RH at 15℃ (59℉) 50 to 90% RH at 20℃ (68℉)
25 to 98% RH at 25 to 80℃ (77 to 176℉) 45 to 95% RH at 25℃ (77℉)
25 to 80% RH at 90℃ (194℉) 40 to 95% RH at 30 to 90℃
(86 to 194℉)
Fluctuation1)
(±%RH)
at 60%RH / 55℃
0.3
0.4
0.3
0.5
0.6
Variation1)
(±%RH)
at 60%RH / 55℃
3.0
Refrigeration System Mechanical single stage
refrigerator system
(air-cooled condenser)
Mechanical dual stage
refrigerator system
(air-cooled condenser)
Refrigerant R-404A (CFC-free) R-404A (1st step), R-23 (2nd step)
Capacity(W) 1500 3000
Cooler Plate fin cooler
Heater Material Incoloy sheath heating element
Drying bulb(W) 2000 3000
Humidity
bulb(W)
1500 2000
Sensor Temperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W) 4 sets of sirocco fan (4 X 90W)
Water tank Capacity 15L (0.53cu ft) - Cartridge type Direct water supplying system
Water
quality
pH6.2 to 7.2/ Electrical conductivity 20?/cm to below
Dimensions
(WxDxH)
Interior
(mm/inch)
500x630x
600
/ 19.7x24.8
x23.6
600x630x
800
/ 23.6x24.8
x31.5
600x850x
800
/ 23.6x33.5
x31.5
1000x800x
1000
/ 39.4x31.5
x39.4
1000x1000x
1000
/ 39.4x39.4
x39.4
Exterior
(mm/inch)
1025x1035x
1530
/ 40.4x40.7
x60.2
1120x1070x
1730
/ 44.1x42.1
x68.1
1120x1240x
1730
/ 44.1x44.8
x68.1
1570x1245x
2060
/ 61.8x49.0
x81.1
1570x1445x
2060
/ 61.8x56.9
x81.1
Viewing
window
(mm/inch)
200X300 / 7.9X13.0 270X330 / 10.6X13.0
Net weight
(kg/lbs)
310 ±10
/ 683.4 ±22.0
375 ±10
/ 826.7 ±22.0
400 ±10
/ 881.8 ±22.0
- -
Cable access hole Basically one hole provided/ ? 50mm (2.0")
Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2")
Electrical Requirements
(230V)
60Hz/ 1ph/ 23.0A 60Hz/ 1ph/ 39.0A
Cat. No. AAH80011 AAH80021 AAH80031 AAH80041 AAH80051
Electrical Requirements
(230V)
50Hz/ 1ph/ 13.3A 50Hz/ 1ph/ 22.5A
Cat. No. AAH80012 AAH80022 AAH80032 AAH80042 AAH80052
Electrical Requirements
(380V)
50Hz/ 3ph/ 7.7A 50Hz/ 3ph/ 13.0A
Cat.No. AAH80018 AAH80028 AAH80038 AAH80048 AAH80058
1) Technical data. (according to DIN 12880, IEC 60068)
CE Certification only for the TH-G-180, 300, 408
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%

Model TH-I-180 TH-I-300 TH-I-408
Chamber volume (L/cu ft) 180 / 6.4 300 / 10.6 408 / 14.4
control system
BDBC2 system - Balanced Dehumidifying & Bath Cooling Control
Controller
Programmable, Touch screen type controller (5.7" B/W monitor)
Temperature Range(℃/℉)
-35 to 150 / -31 to 302 - without humidity
* Best programmable control range: -35 to 140 / -31 to 284
Fluctuation1)(±℃/℉)
at 55℃ / 60%RH
0.1 / 0.18 0.2 / 0.36 0.2 / 0.36
Variation1)(±℃/℉)
at 55℃ / 60%RH
0.6 / 1.08 0.5 /0.9 0.5 / 0.9
Time Heating-without
humidity(Min.)
50 From -35℃ to 120℃ (-31℉ to 248℉)
Cooling-without
humidity(Min.)
60 From 20℃ to -35℃ (68℉ to -40℉) on single point control *
Humidity Range(%RH)
30 to 80 at 10℃ (50℉)
20 to 98 at 25 to 80℃ (77 to 176℉)
20 to 80 at 90℃ (194℉)
Fluctuation1)(±%RH)
at 60%RH / 55℃
0.3 0.4 0.3
Variation1)(±%RH)
at 60%RH / 55℃
3 3 3
Refrigeration System
Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant
R-404A
Capacity(W)
1500
Cooler
Plate fin cooler
Heater Material
Ni-Cr Wire Heater / SUS sheath Heater
Drying bulb(W)
2000
Humidity bulb(W)
1500
Sensor Temperature
Pt 100
Humidity
Electronic sensor - Free of drying a wet pack and good reaction time
Material Interior
Stainless steel #304
Exterior
Stainless steel #304
Insulation
Polyurethane foam 100mm (3.94”)
Door
Glass wool
Air flow
Tangent blower (90W)
Water tank Capacity
15L (0.53cu ft) - Cartridge type
Water quality
pH6.2 to 7.2/ Electrical conductivity 20?/cm to below
Dimensions
(WxDxH)
Interior(mm/inch) 500x630x600
/ 19.7x24.8x23.6
600x630x800
/ 23.6x24.8x31.5
600x850x800
/ 23.6x33.5x31.5
Exterior(mm/inch) 1025x1035x1530
/ 40.4x40.7x60.2
1120x1070x1730
/ 44.1x42.1x68.1
1120x1240x1730
/ 44.1x44.8x68.1
Viewing
windows (mm/inch)
200X330 / 7.9X13.0
Net weight(kg/lbs) 310 ±10
/ 683.4 ±22.0
375 ±10
/ 826.7 ±22.0
400 ±10
/ 881.8 ±22.0
Cable access hole Basically one hole provided/ ? 50mm (2.0")
Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2")
Electrical Requirements (230V) 60Hz/ 1ph/ 23.0A
Cat. No AAH80111 AAH80121 AAH80131
Electrical Requirements (230V) 50Hz/ 1ph/ 13.3A
Cat. No. AAH80112 AAH80122 AAH80132
Electrical Requirements (230V) 50Hz/ 3ph/ 7.7A
Cat. No. AAH80118 AAH80128 AAH80138
1) Technical data. (according to DIN 12880, IEC 60068)
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%

Model TH-GU-300
Chamber volume (L/cu ft) 300 / 10.6
Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling Control
Controller Programmable, Touch screen type controller (5.7" Color monitor)
Temperature Range(℃/℉) -60 to 150 / -76 to 302 - without humidity
* Best programmable control range: -55 to 140 / -67 to 284
Fluctuation1)(±℃/℉)
at 40℃ / 60%RH
0.3 / 0.54
Variation1)(±℃/℉)
at 40℃ / 60%RH
0.5 / 0.9
Time Heating-without
humidity(Min.)
60 From -60℃ to 120℃ (-76℉ to 248℉)
Cooling-without
humidity(Min.)
65 From 20℃ to -60℃ (68℉ to -76℉) on single point control *
Humidity Range(%RH) 40 to 85 at 15℃ (59℉)
25 to 98 at 25 to 80℃ (77 to 176℉)
25 to 80 at 90℃ (194℉)
Fluctuation1)(±%RH) 3
Variation1)(±%RH) 3
Refrigeration System Mechanical dual stage refrigerator system (air-cooled condenser)
Refrigerant R-404A / R-23
Capacity(W) 3000
Cooler Plate fin cooler

Heater

Material Incoloy sheath heating element
Drying bulb(W) 2000
Humidity bulb(W) 1500
Sensor Temperature Pt 100
Humidity Electronic sensor - Free of drying a wet pack and good reaction time
Material Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W)
Water supply Capacity 15L (0.53cu ft) - Cartridge type
Water quality pH6.2 to 7.2/ Electrical conductivity 20?/cm to below
Dimensions
(WxDxH)
Inerior(mm/inch) 600x630x800 / 23.6x24.8x31.5
Exterior(mm/inch) 1120x1070x1730 / 44.1x42.1x68.1
Viewing window
(mm/inch)
200x330 / 7.9x13.0
Net weight(kg/lbs) 395 ±10 / 870.8 ±22.0
Cable access hole Basically one hole provided/ ? 50mm (2.0")
Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2")
Electrical Requirements(230V) 60Hz/ 1ph/ 29.0A
Cat. No. AAH80321
Electrical Requirements(230V) 50Hz/ 1ph/ 29.0A
Cat. No. AAH80332
Electrical Requirements(230V) 50Hz/ 3ph/ 9.7A
Cat. No. AAH80328
1) Technical data. (according to DIN 12880, IEC 60068)
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%
※ Upon request, other sizes of chambers are available. Please contact with us.


Model TC-G-180 TC-G-300 TC-G-408 TC-G-800 TC-G-1000
Chamber volum(L/cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3
Control system Cooling fuzzy control system
Programmable, Touch screen type controller (5.7" B/W monitor)
Controller
Temperature Range(℃/℉) -35 to 150 / -31 to 302
Fluctuation1)(±℃/℉)
at 100℃
0.2 / 0.36
0.1 / 0.18
Variation1)(±℃/℉)
at 100℃
0.9 / 1.62
1.0 / 1.80
0.8 / 1.44
0.4 / 0.72
0.5 /0.9
Time Heating-without
humidity(Min.)
50min, -35℃ to 120℃
(-31℉ to 248℉)
60 From -35℃ to 120℃
(-31℉ to 248℉)
Cooling-without
humidity(Min.)
60 From 20℃ to -35℃ (68℉ to -31℉) on single point control
Refrigeration System Mechanical single stage refrigerator system
(air-cooled condenser)
Mechanical dual stage
refrigerator system
(air-cooled condenser)
Refrigerant R-404A R-404A (1st step),
R-23 (2nd step)
Capacity(W) 1500
 
3000
Cooler Plate fin cooler
Heater Material Ni-Cr Wire Heater
Drying
bulb(W)
2000 3000
Temperature sensor Pt 100
Materal Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W) 4 sets of sirocco fan (4 X 90W)
Dimensions
(WxDxH)
Interior
(mm/inch)
500x630x
600
/ 19.7x24.8
x23.6
600x630x
800
/ 23.6x24.8
x31.5
600x850x
800
/ 23.6x33.5
x31.5
1000x800x
1000
/ 39.4x31.5
x39.4
1000x1000x
1000
/ 39.4x39.4
x39.4
Exterior
(mm/inch)
1025x1035x
1530
/ 40.4x40.7
x60.2
1120x1070x
1730
/ 44.1x42.1
x68.1
1120x1240x
1730
/ 44.1x44.8
x68.1
1570x1245x
2060
/ 61.8x49.0
x81.1
1570x1445x
2060
/ 61.8x56.9
x81.1
Viewing
windows
(mm/inch)
200X300 / 7.9X13.0 270X330 / 10.6X13.0
Net weight
(kg/lbs)
310 ±10 /
683.4 ±22.0
375 ±10 /
826.7 ±22.0
400 ±10 /
881.8 ±22.0
- -
Cable access hole Basically one hole provided/ ? 50mm (2.0")
Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2")
Interface Basically RS-23C [RS-485(Maximum 9 Units Control)-Optional]
Electrical Requirements
(230V)
60Hz/ 1ph/ 16.2A 60Hz/ 1ph/ 39.0A
Cat. No. AAH81411 AAH81421 AAH81431 AAH81441 AAH81451
Electrical Requirements
(230V)
50Hz/ 1ph/ 16.2A 50Hz/ 1ph/ 22.5A
Cat. No. AAH81412 AAH81422 AAH81432 AAH81442 AAH81452
Electrical Requirements
(230V)
50Hz/ 3ph/ 5.4A 50Hz/ 3ph/ 13.0A
Cat. No. AAH81418 AAH81428 AAH81438 AAH81448 AAH81458
1) Technical data. (according to DIN 12880, IEC 60068)
CE Certification only for the TC-G-180, 300, 408
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%

Model TC-GU-300
Chamber volume(L/cu ft) 300 / 10.6
Control system Cooling fuzzy control system
Conroller Programmable, Touch screen type controller (5.7" Color monitor)
Temperature Range(℃/℉) -60℃ to 150℃ (-76℉ to 302℉) - without humidity
* Best programmable control range: -55 to 140 / -58 to 284
Fluctuation1)(±℃/℉)
at 40℃
0.3 / 0.54
Variation1)(±℃/℉)
at 40℃
0.5 / 0.9
Time Heating(Min.) 60 From -60℃ to 120℃ (-76℉ to 248℉)
Cooling(Min.) 65 From 20℃ to -60℃ (68℉ to -76℉) on single point control
Refrigeration System Mechanical dual stage refrigerator system
(air-cooled condenser)
Refrigerant R-404A (1st step), R-23 (2nd step)
Capacity(W) 3000
Cooler Plate fin cooler
Heater Material Incoloy sheath heating element
Drying bulb(W) 2000
Temperature sensor Pt 100
Material Interior Stainless steel #304
Exterior Stainless steel #304
Insulation Polyurethane foam 100mm (3.94”)
Door Glass wool
Air flow Tangent blower (90W)
Dimensions
(WxDxH)
Interior(mm/inch) 600x630x800 / 23.6x24.8x31.5
Exterior(mm/inch) 1120x1070x1730 / 44.1x42.1x68.1
Viewing window (mm/inch) 270x440 / 10.6x17.3
Net weight (kg/lbs) 375 ±10 / 826.7 ±22.0
Cable access hole Basically one hole provided/ ? 50mm (2.0")
Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2")
Electrical Requirements (230V) 60Hz/ 1ph/ 24.3A
Cat. No. AAH81521
Electrical Requirements (230V) 50Hz/ 1ph/ 24.3A
Cat. No. AAH81522
Electrical Requirements (230V) 50Hz/ 3ph/ 8.3A
Cat. No. AAH81528
1) Technical data. (according to DIN 12880, IEC 60068)
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%


 

A tempered dual windows provided a clear view of your specimen during testing.
Improved lighting provided.


 

A glass inner is provided inside the chamber door so that specimens can be observed.
Applicable to TH-G, I-180, 300, 408L/ TC-180, 300, 408L and TH-CR-270 ONLY.
 


 

Recording range: -60 to 150℃/ 0 to 100% RH
Paper wide: 100mm
Portable type
6 dots (Temperature: 5 dots, Humidity: 1 dot)
Digital display
Free power supply (100V to 240V)


 

A through hole of 50 or 80mm dia. (2.0 or 3.2" dia.) is provided on the wall of chamber to
allow electrical cables to be introduced into the chamber. A 50mm hole is provided,
maximum two holes (50 or 80mm) are optional.
Equipped with rubber plug.
Standard 50mm hole is on the left side.


 

Water supply system to supply pure water for humidification.

Cartridge type water tank for easy water supply
Maintenance can be done easily from the front side
A center window allow to check the amount of water remaining easily


 

A signal light to light up when malfunction occurs. Can be located upper plate of unit.


 

Stainless steel and electro polished shelf system is removed easily without using tools for
easy cleaning.


 

Stainless steel shelf system





 